M-216 OPERATOR’S MANUAL357 West 2700 South • Salt Lake City, Utah 84115 • Phone: (800) 496-3463 • Fax: (801) 484-6906 • http://www.comtek.comM-216Wir
Page 9M-216 FREQUENCY CHARTCHANNEL(SWITCH POSITION)FREQUENCY0102030405060708091011121314151617182122232425262728293031323334353637383940216.0125 MHz21
Page 10CHANNEL FREQUENCY1915243136216.0125 MHz216.2125 MHz216.3625 MHz216.5875 MHz216.7625 MHz216.8875 MHzGROUP A216 MHzWIDE-BANDFREQUENCY GROUPSFor C
Page 11Optional Accessories1. NBC 9-2C Battery charger2. NH9-150 Rechargeable batteries3. P1 Universal pouch4. BC-216 Snap-on belt clip(suppli
M-216 SPECIFICATIONSPage 12Audio Input:• Microphone input impedance for electret type microphone - 3000 ohm• Aux/Line input impedance - 10 k ohm
357 West 2700 South • Salt Lake City, Utah 84115Phone: (800) 496-3463 • Fax: (801) 484-6906Web Page: http://www.comtek.comM-216 WARRANTY AND SERVICE
INTRODUCTIONPage 1The M-216 wireless microphonetransmitter offers the ultimateperformance and versatility for assistivelistening, language interpretat
Setupa. Check to ensure that the M-216 transmitter’s radio frequency channel isthe same as the associated COMTEK receiver’s channel. (Channels arei
Page 3Frequency Selection (216-217 MHz)The M-216 transmitter can operate on one of 57 available channels between216 MHz and 217 MHz. COMTEK’s channel
Low Battery IndicatorThe LED on the top of the transmitterindicates the status of the battery aswell as indicating that the unit is turnedon. When tu
Page 5M-216 OPERATING INSTRUCTIONSAuxiliary Audio Input OperationThe M-216 transmitter may transmit from avariety of audio sources such as tape and C.
Page 6Belt clip installationM-216 SNAP-ON BELT CLIP (Included)Belt clip removalc. Turn on the transmitter with program from the audio source being f
Page 7Battery Charge To charge the M-216 with the NBC 9-2C charger:1. Make sure that a Ni-MH or Ni-Cad rechargeable battery is used. (Alkaline b
M-216 CONTROLS! COMPAND AUTO / OFF SWITCH: This switch overridesthe automatic selection of the companded channels tonon-companded operation." CHA